Home > Products > Spectroscopy > Fluorascence > FP-6500/6600

FP-6500/6600 Fluorescence Spectrometer


The FP-6500 is the research-grade spectrofluorometer with a minimum 1 nm resolution and a highest sensitivity S/N ratio 200 or greater for the Raman band of water.

The FP-6500 is especially designed to keep in mind in order to meet requirements in biochemistry as kinetics, stopped-flow, titration, or anisotropic measurements.

The FP-6500 is designed to keep GLP/GMP compliance in mind. Built-in low pressure Mercury lamp and UV cut filter enable to the GLP/GMP compliance with validation software which is available as standard.

The FP-6600 is a factory optional model of the FP-6500 which can be covered emission measurement of NIR region up to 1010 nm.

Features

Large Throughput Optics
The sensitivity is one of most important factor in performance of Fluorescence Spectrophotometer. The FP-6500 is proud of S/N ratio for Raman band of water at 350 nm is greater than 200:1 (SBW: 5 nm on both EX and EM, response: 2 sec., peak-to-peak).

Meeting the Requirements for Biochemistry
A trigger switch for starting measurement is available on the main unit as standard, and also enables to control by an operation on the PC. This function is useful to perform Kinetics analysis. Optional time course software accomplished fast response of 0.1 millisecond, and is very effective for stopped-flow measurement.

Half slit height(L5 and L10 nm) functions for spectral bandwidths enables to meet the requirements on sample measurements using micro cell.

High Quality Optical System
The optical system utilizes high quality components including a DC-powered 150W Xenon lamp (in a sealed housing), holographic concave grating monochromators, fast EX and EM direct scanning drive, variable slits and horizontal sample illumination. Especially, minimum spectral bandwidth of 1 nm on both EX and Em monochromators can get high resolution data.

Horizonal Slit Image
The sample illumination optics incorporate an all reflective image rotation optical system to obtain high emission yields. Rotating the slit image of the monochromator formed on the sample cell by 90 deg., the observed volume of the sample illumination is enlarged by the slits length-to-width ratio, resulting in higher emission intensity providing an increase in sensitivity.

GLP/GMP Compliance
The FP-6500 is designed to keep GLP/GMP compliance in mind. Built-in low pressure Mercury lamp and UV cut filter enables to the GLP/GMP compliance with validation software which is available as standard. Validation program is based on JAIMAS, and it is not necessary to carry out traceability on jig.

Phosphorescence Measurement
The FP-6500 is supplied Phosphorescence spectrum measurement program and Phosphorescence lifetime measurement program as standard.

Compact Design
The compact optical bench is housed in a rugged case measuring only 550 (W) x 540 (D) x 300 (H) mm.


Specifications

FP-6500
Ex wavelength range: 220~750nm (200 ~ 850 nm as option)
Em wavelength range: 220~750nm (220 ~ 850 nm as option)
Minimum resolution: 1nm
Minimum response: 0.01 sec. (0.1msec as option)
S/N ratio: >200:1 for Raman band of water (SBW: 5 nm on both EX and EM, response: 2 sec., peak-to-peak)

FP-6600
Ex wavelength range: 220~850nm
Em wavelength range: 220~1010nm
Minimum resolution: 1nm
Minimum response: 0.01 sec. (0.1msec as option)
S/N ratio: >100:1 for Raman band of water (SBW: 5 nm on both EX and EM, response: 2 sec., peak-to-peak)

Accessories
Thermostatted cell holders
Micro cell holder
Single Peltier cell holders
Multi-position Peltier cell holder
Flow cells and sippers
Depolarisation cell holders
Automatic titrator
Stopped-flow accessories
Microplate reader
Integrating sphere
High temperature powder sample accessory
And many more!